{"id":2030,"date":"2026-04-27T11:44:33","date_gmt":"2026-04-27T11:44:33","guid":{"rendered":"https:\/\/protasoftware.com\/fr\/wiki\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/"},"modified":"2026-04-27T11:44:33","modified_gmt":"2026-04-27T11:44:33","slug":"comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025","status":"publish","type":"wiki","link":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/","title":{"rendered":"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025"},"content":{"rendered":"<div>ProtaStructure prend en charge de nombreux codes sismiques, dont IBC, UBC, EC8,<br \/>\nNSCP, SNI, ainsi que les normes indienne, tha\u00eflandaise, p\u00e9ruvienne, colombienne et turque. Le<br \/>\nlogiciel d\u00e9finit les param\u00e8tres sismiques dans un assistant simple d&rsquo;utilisation. Les spectres<br \/>\n\u00e9lastiques et de calcul, horizontaux et verticaux, sont calcul\u00e9s automatiquement \u00e0 partir des<br \/>\nparam\u00e8tres du code. Des spectres sp\u00e9cifiques au site peuvent aussi \u00eatre introduits. Les sources<br \/>\nde masse sont calcul\u00e9es automatiquement, avec prise en compte de la participation variable des<br \/>\ncharges d&rsquo;exploitation. <\/div>\n<div><\/div>\n<div>Une fois les param\u00e8tres sismiques saisis, les charges sismiques statiques<br \/>\nsont calcul\u00e9es automatiquement. Elles sont appliqu\u00e9es aux niveaux d&rsquo;\u00e9tage. Vous pouvez v\u00e9rifier les<br \/>\nchargements sismiques et les r\u00e9sultats des analyses sismiques dans un mod\u00e8le analytique de<br \/>\npointe.<\/div>\n<div><\/div>\n<div>Dans cette vid\u00e9o, vous apprenez \u00e0 g\u00e9rer les param\u00e8tres sismiques dans<br \/>\nProtaStructure, avec Mustafa Tan, responsable produit chez Prota Software<br \/>\n(ing\u00e9nieur civil, MSc). Vous apprenez aussi \u00e0 g\u00e9rer les options de<br \/>\ndiaphragme.<\/div>\n<div>\n<p class=\"MsoNormal\" style=\"text-align: justify\"><\/p>\n<div><\/div>\n<\/p>\n<div><\/div>\n<\/div>\n<div><\/div>\n<div><span class=\"KB_New_Editor_Highlights\" style=\"margin: 10px 0px;position: relative;padding: 10px 10px 10px 40px\"><img decoding=\"async\" alt=\"Notes\" data-image=\"contentStyle\" style=\"position: absolute;left: 12px;top: 14px;width: 15px\" data-type=\"non-resize\" src=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png\"><\/p>\n<div>Vous<br \/>\ntrouverez des informations d\u00e9taill\u00e9es dans les articles ci-dessous :<\/div>\n<ol>\n<li style=\"list-style-type: disc\"><a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/seismic-analysis-to-eurocode-8\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Analyse sismique selon l&rsquo;Eurocode 8<\/b><\/a><b><br \/><\/b><\/li>\n<li style=\"list-style-type: disc\"><a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/seismic-analysis-to-philippines-nscp2015\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Analyse sismique selon NSCP 2015 (Philippines)<\/b><\/a><b><br \/><\/b><\/li>\n<li style=\"list-style-type: disc\"><a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/seismic-analysis-to-indonesia-sni-1726-2019\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Analyse sismique selon SNI 1726:2019 (Indon\u00e9sie)<\/b><\/a><b><br \/><\/b><\/li>\n<li style=\"list-style-type: disc\"><a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/seismic-analysis-to-india-nbc-2016\" target=\"_blank\" rel=\"noopener noreferrer\"><b>Analyse sismique selon IS 1893-201 (Inde)<\/b><\/a><\/li>\n<\/ol>\n<div>Vous pouvez aussi apprendre \u00e0 g\u00e9n\u00e9rer les combinaisons de charges sismiques et \u00e0 v\u00e9rifier les r\u00e9sultats dans l&rsquo;article<a href=\"https:\/\/support.protasoftware.com\/portal\/en\/kb\/articles\/seismic-load-basic-guide#General\" target=\"_blank\" rel=\"noopener noreferrer\"> <b>Charge sismique &#8211; Guide de base<\/b><\/a>.<\/div>\n<p><\/span><\/p>\n<div><\/div>\n<\/div>\n<div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>ProtaStructure prend en charge de nombreux codes sismiques, dont IBC, UBC, EC8, NSCP, SNI, ainsi que les normes indienne, tha\u00eflandaise, p\u00e9ruvienne, colombienne et turque. Le&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"template":"","meta":{"_whitepaper_youtube_videos":"","_whitepaper_youtube_url":"","_whitepaper_youtube_thumbnail":"","footnotes":""},"categories":[53],"whitepaper_topic":[],"whitepaper_product":[],"whitepaper_type":[],"class_list":["post-2030","wiki","type-wiki","status-publish","hentry","category-protastructure-protadetails-videos"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.9 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025 - Prota Software<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Prota Software\" \/>\n<meta property=\"og:description\" content=\"ProtaStructure prend en charge de nombreux codes sismiques, dont IBC, UBC, EC8, NSCP, SNI, ainsi que les normes indienne, tha\u00eflandaise, p\u00e9ruvienne, colombienne et turque. Le&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/\" \/>\n<meta property=\"og:site_name\" content=\"Prota Software\" \/>\n<meta property=\"og:image\" content=\"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Prota Software\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/\",\"name\":\"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025 - Prota Software\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png\",\"datePublished\":\"2026-04-27T11:44:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/#primaryimage\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png\",\"contentUrl\":\"https:\\\/\\\/protasoftware.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/support\\\/manuels-techniques\\\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/\",\"name\":\"Prota Software\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/protasoftware.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025 - Prota Software","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/","og_locale":"fr_FR","og_type":"article","og_title":"Prota Software","og_description":"ProtaStructure prend en charge de nombreux codes sismiques, dont IBC, UBC, EC8, NSCP, SNI, ainsi que les normes indienne, tha\u00eflandaise, p\u00e9ruvienne, colombienne et turque. Le&hellip;","og_url":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/","og_site_name":"Prota Software","og_image":[{"url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_title":"Prota Software","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/","url":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/","name":"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025 - Prota Software","isPartOf":{"@id":"https:\/\/protasoftware.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/#primaryimage"},"image":{"@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/#primaryimage"},"thumbnailUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png","datePublished":"2026-04-27T11:44:33+00:00","breadcrumb":{"@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/#primaryimage","url":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png","contentUrl":"https:\/\/protasoftware.com\/wp-content\/uploads\/2026\/04\/prota-doc-7a6ce99b57d0e8ae8970f8144288d23d.png"},{"@type":"BreadcrumbList","@id":"https:\/\/protasoftware.com\/fr\/support\/manuels-techniques\/comment-gerer-les-parametres-sismiques-dans-protastructure-suite-2025\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/protasoftware.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Comment g\u00e9rer les param\u00e8tres sismiques dans ProtaStructure Suite 2025"}]},{"@type":"WebSite","@id":"https:\/\/protasoftware.com\/fr\/#website","url":"https:\/\/protasoftware.com\/fr\/","name":"Prota Software","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/protasoftware.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/wiki\/2030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/wiki"}],"about":[{"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/types\/wiki"}],"author":[{"embeddable":true,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":0,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/wiki\/2030\/revisions"}],"wp:attachment":[{"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/media?parent=2030"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/categories?post=2030"},{"taxonomy":"whitepaper_topic","embeddable":true,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/whitepaper_topic?post=2030"},{"taxonomy":"whitepaper_product","embeddable":true,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/whitepaper_product?post=2030"},{"taxonomy":"whitepaper_type","embeddable":true,"href":"https:\/\/protasoftware.com\/fr\/wp-json\/wp\/v2\/whitepaper_type?post=2030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}