Remaining Available Seats
Europe
8
South America
8
Africa
7
Middle East
10
Asia
0
10 Limited Seats Per Region
Extension 10 Additional Seats
01-12 December
Claim Your Special Offer
Request a Quote
X
Remaining Available Seats
Europe
8
South America
8
Africa
7
Middle East
10
Asia
0
10 Limited Seats Per Region
Extension 10 Additional Seats
01-12 December
Claim Your Special Offer
Request a Quote
X

"Discover the power of ProtaStructure Suite 2024, where design, modeling, analysis, and detailing converge in a single, seamless click. Elevate your structural engineering to new heights of efficiency and precision."

Social Media

White Paper February 8, 2020

Beam-Column Joint Shear Design (NBCI 2016 – Annex F)

Summary

Beam-Column Joint Shear Checks in ProtaStructure According to NBCI 2016

Beam-column joint shear checks are a crucial aspect of structural design, particularly in situations where opposite beams are not aligned in the same line or level at a joint. These misalignments require engineers to carefully evaluate the tolerance limits for both vertical alignment and plan placement. If the beams exceed the prescribed tolerance limits, they are treated as separate joints to ensure accurate analysis and safety compliance.

ProtaStructure simplifies these critical checks by incorporating detailed calculations based on NBCI 2016 – Annex F. The software automates the process of evaluating joint shear limits, offering engineers a reliable way to ensure compliance with design codes. In this document, a numerical example demonstrates the process through a 4-story residential building model, detailing the material properties, reinforcement grades, member configurations, and construction drawings. The results of the joint shear checks are verified and displayed using ProtaStructure’s intuitive interface and automated reporting features.

Importance of Beam-Column Joint Shear Checks

Performing accurate joint shear checks is essential to maintain structural safety and integrity. Neglecting these checks can lead to joint failures, compromising the entire structure. By adhering to NBCI 2016 standards, engineers ensure that joint designs can withstand applied loads and resist potential failure mechanisms.

ProtaStructure’s advanced calculations help engineers account for:

  • Shear forces acting at the joint.
  • Load redistribution due to beam misalignment.
  • Material behavior under stress.

Learn and Explore Real-World Applications

This document not only explains the process of beam-column joint shear checks but also highlights how ProtaStructure improves efficiency in structural engineering design.

Explore Real Projects

Visit our Projects Gallery to see how ProtaStructure is used in real-world structural projects, from residential buildings to industrial structures.

Customer Success Stories

Discover customer success stories that showcase how engineers rely on ProtaStructure to solve complex structural challenges efficiently and effectively.

Conclusion

Beam-column joint shear checks, especially for non-aligned beams, are fundamental to structural safety and code compliance. ProtaStructure not only streamlines these calculations but also provides robust reporting and verification tools that enhance project accuracy and safety. By automating these checks in accordance with NBCI 2016 – Annex F, ProtaStructure ensures that engineers can confidently meet design requirements and maintain the integrity of their structures.